CONTINUOUS EMISSION GASES MONITORING CONTROL EQUIPMENT "TECTROL" FOR:

  • 2 (TWO) GASES (O2, CO), and
  • 5 (FIVE) GASES (O2, CO, SO2, NOx, HCI)

Principle: “Isocinetic” (constant speed of gases)
This Continuous Emission Monitoring System works with the established by International Legislation.
Range of Measurement: Adaptable to Customer needs.
Resolution: Lower than 1ppm and 0, 1% in volume to 02 (Oxygen)
Accuracy: Better than 1%
Sensibility: Lower than 1ppm and 0.1% in volume to O2 (Oxygen)

Our Equipments work under the PC control. They are with Programmable from the PC or a Touch-Screen. So it does not need Special Recorders, but the Operator may check it state through the Touch-Screen located in the front side or from the PC.

“These Equipments, are built specifically to measure Gases in Chimney”


CONTINUOUS EMISSION MONITORING CONTROL EQUIPMENTS “TECTROL” FOR:

  • 4 (FOUR) GASES (O2, CO, NOx, SO2) or
  • 7 (SEVEN) GASES (O2, CO, NOx, SO2, HCI, HF, HCt)

Principle: “Isocinetic” (constant speed of gases) This Continuous Emission Monitoring System works with the established by International Legislation. Range of Measurement: Adaptable to Customer needs.

  • Resolution: Lower than 1ppm and 0.1% in volume to 02 (Oxygen)
  • Accuracy: Better than 1%
  • Sensibility: Lower than 1ppm and 0.1% in volume to O2 (Oxygen)

Our Equipments work under the PC control. They are with Programmable from the PC or a Touch-Screen. So it does not need Special Recorders, but the Operator may check it state through the Touch-Screen located in the front side or from the PC.

"These Equipments, are built specifically to measure Gases in Chimney"


PARTICULATE MATERIAL (PM) AND OPACITY

CONTINUOUS MONITORING EQUIPMENT TO PARTICULATE MATERIAL (PM)

This Equipment gives direct information of Particulate Material in mg/Nm3. It uses an advanced design based on electrodynamics technologies, and it is homologated by the TA LUFT.

The exit signal of the Equipment entries to the PC language and it is entered to the Central Computer, keeping in this way every old value registered with the rest of measured gases.


PARTICULATE MATERIAL (PM) AND OPACITY

EQUIPMENT OF CONTINUOUS MONITORING FOR OPACITY

The Equipment provides a direct reading in terms of density of the Opacity according to Ringelmann Scale measured from 0 up to 100%.

The signal of the Equipment input to the PC and it is entered to the Central Computer, keeping in this way every old value registered with the rest of measured gases.

"These Equipments, are built specifically to measure Gases in Chimney"